3.3.1 Lighting the fire manually with firewood
The fire lighting method is very important for starting combustion quickly and efficiently.
1) Open the damper under the door (pulled fully out). The primary damper is used at the start to get the
fire going, while the secondary air intake keeps the fire burning evenly. The illustration below shows
the stove seen from the front with the dampers indicated.
2) Place a log of wood crosswise in the combustion chamber and put 2 firelighters close to the log.
Light the firelighters and quickly put a new log close to the firelighters and several small logs at an
angle above it. Air must be able to reach the firelighters, but the logs should be touching to "warm"
each other.
3) Keep the door approx. 1 cm ajar, until the glass is too hot to touch. Then close the door. When there
are distinct, visible flames and the fire has taken hold, close the primary air intake/damper.
Use edge of door to read position of inlet air
1: Fully open primary-, secondary- and tertiary air inlet. This position can be maintained with the Aduro key,
which must be placed in the two holes.
2: Closed primary air inlet, fully open secondary- and tertiary air inlet.
3: Closed primary air inlet, half way closed secondary air inlet and fully open tertiary air inlet.
4: Closed primary- and secondary air inlet, fully open tertiary air inlet.
5: Regulator pushed all the way in. All air inlet closed (only used when burning wood pellets).
49