Start procedure
Switch device on
1. Ensure that the condensation tank is empty and
inserted correctly. Otherwise, the device will not
operate!
2. Insert the mains plug into a properly secured
mains power socket.
3. Check whether the condensation tank indicator
light (8) is out.
4. Switch on the device at the mains switch (10).
5. The first time that you use the device, use the
arrow button (12) to set the desired level of
humidity to < 30 %.
6. Let the device run for approx. one hour.
7. Use the arrow buttons (12 and 13) to adjust the
desired level of humidity to between 30 and 80 %.
8. Regulate the device fan speed by pressing the
"FAN SPEED" button (14).
"Normal" operation mode
The built in humidistat switches the defrost back on or
off depending on the humidity.
"Continuous" operation mode
The device dehumidifies the air constantly and
regardless of the amount of humidity in the air.
"Automatic defrost" operation mode
Upon cooling, the moisture in the room air condenses
and covers the evaporator fins with ice, regardless of
the air temperature and the relative humidity.
Automatic defrost switches on the defrost cycle when
necessary. During the defrost phase, dehumidifying is
temporarily paused and the "defrost" symbol (18) is
shown. Automatic defrost is activated automatically in
"Normal" operation mode.
B - 7
Automatic defrost
If the room temperature is below 15 °C, the
evaporator
dehumidifying. The device then carries out an
automatic defrost.
• The automatic defrost is interrupted as soon as the
mains switch (10) or the arrow buttons (12 or 13)
are pressed.
Do not turn off the device during the automatic
defrost. Do not remove the mains plug from the mains
socket.
Adjusting the operating time
1. Press the "TIMER" button (11) to set the operating
time of the device. Keep pressing the button until
the desired operating time is displayed (between
1 and 12 hours). After the operating time has
passed, the device automatically switches off.
2. To switch this function off, press the "TIMER"
button (11) again until the "00" operating time is
displayed.