Startup

Airflow control

The combustion air is regulated at two
points:
· On the pressure side by means of the
opening gap between the turbulator
and burner tube.
· On the suction side by means of the
air flap actuated by servomotor Y10.
Airflow control in the burner head
has an effect on the air quantity, as well
as on the mixing zone and the air
pressure in the burner tube. Turn
adjustment screw A clockwise to
increase airflow, and anticlockwise to
decrease it.
clockwise = increased airflow
anticlockwise = reduced airflow
· Adjust dimension Y corresponding to
table of settings.
Servomotor Y10
1
Four adjustable red cams
2
Marking to indicate cam setting
relative to scale no. 4
S
Adjust screws for cams
4
Three scales divided between 0
and 160°
5
Air-flap setting indicator
6
Removable plug-and-socket
connection
Cam function
nd
I
Air-flap setting 2
stage
II
Air shut-off
III
Activation of solenoid valve
nd
2
stage
st
IV
Air-flap setting 1
stage
m
Setting
Control cam III must lie between
control cam I and IV.
03/2005 - Art. Nr. 13 018 069A
Suction-side airflow regulation is carried
out using an air flap.
This is actuated by servomotor Y10.
The position of the air flap is
determined by adjusting cams I - IV.