Herunterladen Inhalt Inhalt Diese Seite drucken

Mechanical Data; Electrical Data - Hengstler AX73 Installationsanleitung

Vorschau ausblenden Andere Handbücher für AX73:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN

4. Mechanical data

Housing diameter
Shaft diameter
Mounting
Shaft load max.
Speed max.
Nominal speed
Torque
Moment of inertia
Protection class (EN 60529/ A1:2000-02)
Ambient temperature
Storage temperature
Vibration performance (DIN EN 60068-2-6:2008)
Shock resistance (DIN EN 60068-2-27:2010)
Connection
2)
Material Shaft
Material Housing
Weight
1)
no standing water allowed at the shaft entrance or cable entrance or at the ball bearing.
2)
without cable gland

5. Electrical data

Interface
General design
Supply voltage
Current w/o load max.
Recommended external fuse
Power consumption
Resolution
EMC
3)
Clock frequency
Inputs
18 of 20
73,5 / 76mm
10mm
Clamping flange, bores 3xM6
radial 100N, axial 40N
3000 rpm
1500 rpm
≤ 4 Ncm
2
30 gcm
approx.
housing IP66/IP67, bearing IP67
-40°C ... +70°C
-20°C ... +80°C
100m/s
2)
(10 ... 60Hz 1.5mm; 60 ... 2000Hz 100m/s
1000m/s
2)
(6ms)
Terminal box with 2 x M20x1,5 screw thread, radial
Stainless Steel 1.4104 / AISI 430F
Stainless Steel 1.4404 / AISI 316L
approx. 2200g
SSI, BiSS
as per EN 61010 - 1, protection class III
contamination level 2, overvoltage class II
10 - 30V DC (encoder is polarity protected)
200 mA
T 0,25 A
approx.. 1,5W to 2W
According to ordering code.
Noise emission as per EN 61326-1 Group 1, Class B;
Noise immunity as per EN 61326 - 1 Class A
100 ...1000 kHz
4)
Direction
Item number: 2-539-198, Version: 3 241016TK
1)
2
)

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ip67

Inhaltsverzeichnis