Press and hold F button, then press R button to select inverted chaser direction.

6.1.4 Select output level

F + D/S button to select CRO or NOR
NOR refers to 0-100% dimming.
CRO means dimming level is greater than 50%, full on is activated, otherwise, stand by is
activated.

6.1.5 Select operating mode

F + SINGLE button to select MASTER or DMX mode.

6.1.6 Reset

E. F + SINGLE +RESET button to perform a reset for the whole system , which enable to return to initial
condition.
6.1.7 Full on & stand by ( located on the foot control)
Press FULL ON to activate full on function of whole channel output, display shows FUL. press
STAND BY to turn off whole channel and STD appears.

6.2 DMX mode

When the DMX indicator is lit, this unit is used as a DMX dimmer pack, Display shows "DMX".

6.2.1 Set DMX address of any one channel

Press channel button ,corresponding indicator will blink, and the DMX address of corresponding channel will
appear in DISPLAY. Using up button or down button to select desired DMX address followed by pressing
corresponding channel button, corresponding indicator is off indicating information of entry is confirmed.
Then the information in DISPLAY screen returns to initial condition.

7. CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.

7.1 Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.