What to do if ...

Correcting Malfunctions

A malfunction may be caused by only a minor fault that you can rectify
yourself using the following instructions. Do not perform any other work on
the appliance if the following information does not provide assistance in
your specific case.
Warning! Repairs to refrigerators/freezers may only be performed by
qualified service engineers. Improper repairs can give rise to significant
hazards for the user. If your appliance needs repairing, please contact your
specialist dealer or our Customer Service.
Malfunction
Appliance does not work, no
pilot light is illuminated.
Green light does not light up,
yellow light lights up when
fast freeze fuction is activa-
ted, appliance is on.
Yellow light does not light up,
when fast freeze fuction is
activated, appliance is on.
Appliance cools too much.
Possible Cause
Appliance is not switched on Switch on the appliance.
Mains plug is not plugged in
or is loose.
Fuse has blown or is defective.
Socket is defective.
Green light faulty.
Yellow light faulty.
Temperature is set too cold.
Remedy
Insert mains plug.
Check fuse, replace if neces-
sary.
Mains malfunctions are to be
corrected by an electrician.
Please inform your customer
service
Please inform your customer
service
Turn the temperature regula-
tor to a warmer setting tem-
porarily..