11. tECHNICaL SPECIfICatIoNS
Operating voltage .................................9 v (PP3) battery
Response time ......................................<1 second
Spectrum ..............................................8 - 14 µm
Emissivity ..............................................Adjustable from 0.1 to 1.00
Resolution .............................................0.1 °C (IR and contact temperature measurement)
IR measuring spot size .........................30:1
Laser .....................................................Power <1 mW, laser class 2,
..............................................................wave-length 630 - 690 nm
Operating temperature .........................0 to 50 °C
Operating humidity ...............................10 - 90% RH
Storage temperature .............................-10 to 60 °C
Storage humidity ...................................10 - 80% RH
Weight ..................................................180 g
Dimensions ...........................................230 x 56 x 100 mm
Accuracy (at 23 - 25 °C ambient temperature, emissivity 0.95)
temperature measuring range
-50 to +20 °C
+20 to +500 °C
500 to 900 °C
Accuracy without temperature sensor; measurement uncertainty of the temperature sensor must be added.
temperature measuring range
-50 to 1,000 °C
1000 to 500 °C
The supplied wire temperature sensor is suitable for temperature measurements of up to 200 °C.
accuracy of Ir measurement
±3.5 °C
±2 % of the measured value ±1.5 °C
±2 % of the measured value
accuracy of contact temperature measurement (type k)
±1.5 % of the measured value ±3.5 °C
±1.5 % of the measured value ±2 °C
29