3
3
1
1. Control panel.
Light
:
move the switch to the right or press the button to switch
on.
Extraction speed
:
Move the switch to the right or press the next button to
increase extraction speed (or open the electric shutter )
2. Grease filters.
3. Lamp covers
(or halogen lamps, depending on the model).
4. Telescopic flue.
Grease filters:
Metal grease filters have an unlimited
life and should be washed once a
month either by hand or in a
dishwasher at a low temperature and
with a short cycle.
Note: Washing in a dishwasher can
cause grease filters to turn white, but
this in no way affects efficiency.
a. press the handle to remove the
filter
b. remove it.
Wash the filter and leave it to dry, proceeding in reverse
order to refit it.
Bulb/s:
Remove the filters and remove the burnt-out bulb.
Refit the filters.
5019 318 33287
4
2
.
a
b
D
GB
F
NL
Replacing the halogen bulbs:
1. Disconnect the hood from the mains power supply.
WARNING: Wear gloves.
2. Use a small screwdriver to gently prise the lamp cover off
(at the points indicated in Fig.).
3. Remove the burnt-out lamp and fit a new one.
WARNING: Replace using 20W max G4 halogen bulbs
only.
Close the lighting unit (snap-on).
Fitting or changing the carbon filter
(filter versions only).
Change the carbon filter every six months.
1. Remove the grease filters.
2. Fit the filter/s to cover the motor according to the model:
• Align the pins R on the cowl with the slots S, then
turn the filter clockwise until it locks in place
• turn the central handle clockwise.
3. Reverse the above procedure to remove the carbon
filter.
4. Refit the grease filters.
Or
P
I
GR
E