Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages And Error Clearance - Weller WXR 3 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für WXR 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7

Error messages and error clearance

Message/symptom
Display: „- - -
No display function (display
OFF)
No vacuum at desoldering tool
Insufficient vacuum at desolde-
ring tool
Hot air tool has no air
Symbols
Caution!
Read the operating instructions!
Before performing work of any kind
on the unit, always disconnect the
power plug from the socket.
ESD-compatible design and ESD-
compatible workstation
Equipotential bonding
CE mark of conformity
Fuse
Safety transformer
44
Possible cause
Tool has not been detected
Tool defective
No mains supply voltage
Vacuum not connected
Desoldering nozzle clogged
Pump faulty
Filter cartridge on desoldering
tool full
Main filter full
Air hose not connected
Main filter full
Remedial measures
Check connection of tool to
device
Check connected tool
Turn on mains power switch
Check mains supply voltage
Check device fuse
Connect vacuum hose to
vacuum connection
Service desoldering nozzle
using cleaning tool
Change filter cartridge on
desoldering tool full
Change the main filter element
on the soldering station
Connect or check air hose
Change main filter cartridge on
soldering station
Soldering
Desoldering
Hot air
Disposal
Do not dispose of electric tools together
with household waste material! In
observance of European Directive
2012/19/EU on waste electrical and
electronic equipment and its implemen-
tation in accordance with national law,
electric tools that have reached the end
of their life must be collected separately
and returned to an environmentally
compatible recycling facility.
Dispose of replaced equipment parts,
filters or old devices in accordance with
the rules and regulations applicable in
your country.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis