REK33 (RF710/RF1420/BF850/IF850)
Parameter
d1
Main Set point
d2
Differential ( hysteresis )
d3
lower limit of main set point
d4
Upper limit of main set point
d5
Minimum time interval between the disactivation and successive activation on compressor
d6
Max temperature alarm differential
d7
Maximum or minimum temperature alarm delay
d8
Time interval between defrost cycle
d9
Max defrost cycle time
d10
Defrost –end temperature
d11
Time interval for supplementary defrost cycles
d12
Real temperature display delay at defrost end
d13
Compressor function during defrost
d14
Dripping time
d15
Fan operating mode during normal controller
d16
Fan activation delay at controller startup and after defrost
d17
Fan activation temperature at controller startup and after defrosting
d19
Offset ?
d22
Unit of measure, 0=C, 1=F
d23
Compressor function during o probe failure
d24
Compressor on-time during probe failure
d25
Compressor off-time during by probe failure
d27
Serial line address
d34
First defrost cycle after controller startup
d38
Minimum temperature alarm differential
Description
-22 ºC
3 ºC
-24 ºC
-18 ºC
300sec.
50 ºC
99
6h
20min
12 ºC
2min
30 min
0
1min
1
1min
-6 ºC
-5 ºC
0
2
10 min
10 min
0
1
40 ºC
67