• Before you built-under the appliance, install it with
applicable hob from the table.
Type
ZVD 868
ZK 630
ZC 6695
ZC 6675
• Make sure that the recess dimensions are applicable.
• Make sure that there is anti-shock protection for the
installation.
• According to the regulations of force, all parts which
ensure the anti-shock protection must be fixed in such
a way that they cannot be undone without tools.
• Some parts of the oven carry current. Close the appli-
ance with furniture and make sure there are no free
spaces. It prevents electric shock because you cannot
accidentally touch dangerous parts.
• The appliance can be placed with its back and one side
adjacent to the higher appliances or walls. The other
side must be placed to the furniture with the same
height.
• To attach the oven to the built-in cabinet, open the oven
door, put 4 spacers into the holes and tighten the 4
wood screws (see the picture).
Electrical connection
Warning! Only a qualified and competent expert
must do the electrical installation.
• The manufacturer is not responsible if you do not fol-
low these safety precautions.
• Obey the safety precautions when you ground the ap-
pliance.
• Make sure that the rated voltage and type of power on
the rating plate agree with the voltage and the power
of the local power supply.
• This appliance has no mains plug and no mains cable.
• Any electrical component must be installed or replaced
by the Service Centre technician or qualified expert.
• Applicable cable types : H07RN-F, H05RN-F, H05RR-
F, H05VVF, H05V2V2-F (T90), H05BB-F.
18
Maximum power
7600 W
7600 W
6400 W
5800 W
A
B
• Always use a correctly installed shockproof socket.
• Do not use multi-way plugs, connectors and extension
cables. There is a risk of fire.
• Make sure that, after the installation, an engineer can
get access to the oven easily, if repairs or maintenance
are necessary. .
• Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
• Connect the appliance to the mains with a device which
lets you to disconnect the appliance from the mains at
all poles with a contact opening width of minimum 3
mm, eg. safety cut-out or fuse.
• Voltage data is on the rating plate (refer to "Product
description").