Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Opening the switch
1. Insert screwdriver and disengage cover lid
2. Open cover lid
7
Switching symbols and switching diagrams
SMS xx40
Actuator
withdrawn
inserted
On
Off
8
Start-up
Mechanical function test:
• Actuate the safety guard and check the proper switching function.
9

Technical Data

Output circuit
Rated isolation voltage
Rated impulse withstand voltage
Conventional thermal current
Utilization category
B10d (switching cycles without load)
Rated conditional short-circuit
Short circuit protection (melting fuse)
Forced disconnection
Degree of protection
Doc. # BA000778 – 05/2017 (Rev. B)
SMS xx20
Actuator
withdrawn
inserted
Tolerance:
Switchint point ± 0,25mm
Switching force ± 10%
Electrical function test in the safety control circuit:
• Opening the safety guard shall break off the energy of the drive.
• The drive shall only be energized when the safety guard is in its
closed position.
SMS xx20
U
250 V AC
I
U
4.0 kV
IMP
I
10 A
THE
AC-15, Ue/Ie 240 V/3 A
6
2 · 10
1000 A acc. to DIN EN 60947-5-1
6 A gL/gG
acc. to IEC/EN 60947-5-1, Annex K
II, protective insulation
SMS 2xxx
SMS xx40
10 A
AC-15, Ue/Ie 240 V/3 A
10A gL/gG
SMS xx70
SMS xx70
5 A
AC-15, Ue /Ie 240 V/1,5 A
6A gL/gG
EN 9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sms 2x40 seriesSms 2x70 series

Inhaltsverzeichnis