3. Setting of the operating
pa ra me ters
a. Press both front side keys keys and switch
on the supply voltage or, if the supply volt-
age is already on, press both keys simulta-
neously during 5 s.
b. The display shows
c. After releasing the keys, the display shows
c1. Hold the left key pressed and press the right
key to leave the programming operation.
c2. Press the right key to switch to
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alter-
nates between the menu title and the cur-
rent menu item setting. After pressing any
key, only the menu item setting is displayed.
f. Pressing the right key, the menu item
setting will be switched to the next value. If
figures are to be input (e.g. when setting the
scaling factor), select first the decade using
the left key, and then set the value using the
right key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title "EndPro" allows, when
selecting "Yes", to exit the programming
menu and to take over (store) the new
values. If "no" is selected, the programming
routine is repeated, the latest values set
remaining active. They can now be checked
again or modified.
Page 4
4. Programming routine
The first menu item is the selection of the
basic operating mode, which determines the
functions of the device.
Operating mode pulse count-
er. Continued in point 4. of
CODIX 541 on page 4.
Operating mode frequency
meter. Continued in point 4.
of CODIX 542 on page 6.
Operating mode time meter.
Continued in point 4. of
CODIX 543 on page 7.
Pulse counter/Po si ti on indicator
CODIX 541
(CODIX 544: Operating mode pulse counter)
1. Description
• 6-digit display counter with SET/RESET-func-
tion
• Red LED display, character height 14 mm
• Display range from -199 999 to 999 999
• Leading zeros suppression
• Programming via two setting keys on the
front side
• During programming, the display guides the
user with text prompts
• Counter operating modes:
Count input INP A + count direction input
INP B (Cnt.Dir)
Differential count INP A – INP B (up.dn)
Totalising INP A + INP B (up.up)
Count Up/Down INP A 90° INP B x 1 (quAd)
Count Up/Down INP A 90° INP B x 2 (quAd2)
Count Up/Down INP A 90° INP B x 4 (quAd4)
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
• Optional optocoupler output