GRUNDIG Service
Es gelten die Vorschriften und Sicherheitshinweise
gemäß dem Service Manual "Sicherheit", Material-
nummer 720108000001, sowie zusätzlich die eventu-
ell abweichenden, landesspezifischen Vorschriften!
Inhaltsverzeichnis
Technische Daten ..........................................................................1-3
Service-Hinweis .............................................................................1-3
Bedienhinweise .............................................................................1-4
Ausbauhinweise ..........................................................................1-10
Schaltpläne
und Platinenabbildungen .................. 2-1 ... 2-8
Blockschaltplan..............................................................................2-1
Verdrahtungsplan ..........................................................................2-2
Hauptplatte ....................................................................................2-3
Bedienplatte...................................................................................2-7
Ersatzteilliste ................................................. 3-1
Allgemeiner Teil
Allgemeine Hinweise
Achtung: ESD-Vorschriften beachten
Durchführen von Messungen
Bei Messungen mit dem Oszilloskop an Halbleitern sollten Sie nur
Tastköpfe mit 10:1 - Teiler verwenden. Außerdem ist zu beachten, dass
nach vorheriger Messung mit AC-Kopplung der Koppelkondensator
des Oszilloskops aufgeladen sein kann. Durch die Entladung über
das Messobjekt können Bauteile beschädigt werden.
The regulations and safety instructions shall be valid
as provided by the "Safety" Service Manual, part
number 720108000001, as well as the respective
national deviations.
Table of Contents
Seite
General Section ................................ 1-2 ... 1-10
General Notes ...............................................................................1-2
Technical Data ...............................................................................1-3
Service Note ..................................................................................1-3
Operating Hints..............................................................................1-7
Disassembly Hints .......................................................................1-10
Circuit Diagrams
and Layout of PCBs ........................... 2-1 ... 2-8
Block Diagram ...............................................................................2-1
Wiring Diagram ..............................................................................2-2
Main Board ....................................................................................2-3
Keyboard .......................................................................................2-7
General Section
General Notes
Attention: Observe the ESD safety regulations
Carrying out Measurements
When making measurements on semi-conductors with an oscilloscope,
ensure that the test probe is set to 10:1 dividing factor. If the previous
measurement was made on AC input, please note that the coupling
capacitor in the oscilloscope will be charged. Discharge via the item
being checked can damage the components.
1 -
MPixx VP 1000/1GB
Page