Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Wiring - Riello RG4S Montage Und Bedienungs Anleitung

Öl-gebläsebrenner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

3.4 ELECTRICAL WIRING

WARNING
DO NOT EXCHANGE NEUTRAL WITH PHASE
~
50Hz 230V
PE L
N
Limit thermostat
with manual
resetting
7 pin plug
7 pole socket
D1913
Ignition
electrodes
CONTROL BOX
To remove the control-box from the burner, loosen screw (A, fig. 11)
after removing all components, the 7 pin plug and earth wire.
In case of disassembly of the control box, retighten the screw
(A) with a torque wrench setting of 1 – 1.2 Nm.
2310
Main switch
T6A
Regulating
thermostat
Brown
Blue
Black
White
Blue
Burner-earth
NOTES:
– Wires of 1 mm
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
TESTING
Check the shut-down of the burner by open-
ing the thermostats and the lock-out by
darkening the photoresistance.
Hour counter
(230V - 0.1A max.)
Remote lock-out lamp
(230V - 0.5A max.)
Photoresistance
Oil valve
Capacitor
Motor
5
GB
2
section
.
S7072
Fig. 11
A

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

396 t13739650

Inhaltsverzeichnis