1 Werkseinstellungen/factory settings
* nur bei LEd = off, ** nur bei LEd = on, *** je nach Einstellung LEd
* only when LEd = off, ** only when LEd = on, *** depending on LEd setting
Technische Daten
( )* = Werkseinstellung
Isolationskoordination nach IEC 60664-1/IEC 60664-3
Bemessungsspannung ................................................................... 400 V
Bemessungs-Stoßspannung/Verschmutzungsgrad .....................4 kV/III
Sichere Trennung (verstärkte Isolierung) zwischen: ...............................
.................................(A1, A2) - (N, L1, L2, L3) - (11-12-14) - (21-22-24)
Spannungsprüfung nach IEC 61010-1:
(N, L1, L2, L3) - (A1, A2), (11, 12, 14) ................................. 3,32 kV
(N, L1, L2, L3) - (21, 22, 24) ............................................... . 2,21 kV
(A1, A2) - (11, 12, 14) - (21, 22, 24) ................................... 2,21 kV
Versorgungsspannung
VMD420-D-1:
Versorgungsspannung U
.......................... AC 16...72 V/DC 9,6...94 V
s
Frequenzbereich U
............................................................. 15...460 Hz
s
VMD420-D-2:
Versorgungsspannung U
........................................... AC/DC 70...300 V
s
Frequenzbereich U
............................................................. 15...460 Hz
s
Eigenverbrauch .......................................................................... ≤ 4 VA
Messkreis
Messbereich (Effektivwert) (L-N). ................................ AC/DC 0...288 V
Messbereich (Effektivwert) (L-L). ................................. AC/DC 0...500 V
Bemessungsfrequenz f
. ................................................. DC, 15..460 Hz
n
Frequenzanzeige ................................................................ 10...500 Hz
Schaltglieder
Anzahl ................................................................2 x 1 Wechsler (K1, K2)
Arbeitsweise .....................................Ruhestrom n.c. / Arbeitsstrom n.o.
Eigene Einstellungen/
FAC1
0 s
0.5 s
3Ph
OFF
0
3Ph
Technical data
( )* = factory setting
Insulation coordination acc. to IEC 60664-1/IEC 60664-3
Rated insulation voltage .............................................................. 400 V
Rated impulse voltage/Pollution degree. ................................... 4 kV/III
Protective separation (reinforced insulation) between: ..........................
.................................(A1, A2) - (N, L1, L2, L3) - (11-12-14) - (21-22-24)
Voltage test acc. to IEC 61010-1:
Supply voltage
VME420-D-1:
Supply voltage U
Frequency range U
VME420-D-2:
Supply voltage U
Frequency range U
Power consumption . ...................................................................≤ 4 VA
Measuring circuit
Measuring range (r.m.s.) (L-N) .................................... AC/DC 0...288 V
Measuring range (r.m.s.) (L-L) ..................................... AC/DC 0...500 V
Rated frequency f
Frequency range ................................................................ 10...500 Hz
Switching elements
Number of changeover contacts ...................................... 2 x 1 (K1, K2)
Operating principle ................................ N/C operation / N/O operation
User setting
s
s
s
s
(N, L1, L2, L3) - (A1, A2), (11, 12, 14) . ............................... 3.32 kV
(N, L1, L2, L3) - (21, 22, 24) ................................................ 2.21 kV
(A1, A2) - (11, 12, 14) - (21, 22, 24) ................................... 2.21 kV
...................................... AC 16...72 V/DC 9.6...94 V
s
. ........................................................... 15...460 Hz
s
...................................................... AC/DC 70...300 V
s
............................................................ 15...460 Hz
s
....................................................... DC, 15...460 Hz
n
VMD420_D00137_03_Q_DEEN/01.2024
LINETRAXX® VMD420
Einstellbereich/
AL-LED
Setting range
0...300 s
0...300 s
3Ph/3 n
3Ph/3 n
Clr