AEROPAC
5
Assembly
DE
5.1 Installation.requirements
EN
Suitable.installation.position:
in the vicinity of a 230 V AC power
connection.(unit's.maximum.cable.
FR
length:.4.5.m)
for.fixed.connection.via.a.wall-
IT
mounted.outlet.box
not in the immediate vicinity of
NL
radiator thermostats
a smooth and even wall
Ensure.that.no.cables.or.pipes.are.routed.
PL
inside the wall at the unit's designated
position.
RU
Keep the unit free from dirt during
installation.and.before.start-up.
To prevent damage to the high-quality
surface.of.the.unit,.it.is.advisable.to.wear.
suitable.gloves.during.the.installation.
5.2 Additional.requirements.for.
AEROPAC smart / AEROPAC IE smart
The AEROPAC.smart.should.be.installed.
to.be.as.free.from.interference.as.
possible.
The following interferences can have a
negative.influence.on.the.WIFI.signal:
water pipes
stone and concrete walls
metal.objects
air.conditioning.units
wireless devices (e. g. radio
telephones,.baby.monitors,.
Bluetooth.loudspeakers,.etc.)
WIFI.networks.on.the.same.wireless.
channels.(e..g..the.neighbour's.WIFI.
router)
If.energy-carrying.cables.are.routed.in.
parallel.to.data.cables.(ISDN,.DSL,.etc.),.
this could lead to impairment e.g. in the
speed of the data transmission.
36/40
09.2023
Original.operating.instructions
5.3 Recommended.unit.position
5.4 Installation.steps
5.4.1 Installation.of.the.air.pipe
NOTICE
Material damage due to holes in lines or
cables
Damaged.water.lines,.gas.pipes.or.cables.
can cause material damage.
• Prior.to.installation,.check.with.a.test.unit.
that.there.are.no.lines.or.cables.routed.in.
the.wall.at.the.installation.position.
H47.WANS019INT-02