TECHNICAL DATA
BAND SAW
Production code.......................................................................
Rated input ..............................................................................
No-load speed .........................................................................
Blade size ................................................................................
Cutting capacity rectangular stock...........................................
Cutting capacity Pipe ...............................................................
Weight according EPTA-Procedure 01/2003 ...........................
Noise information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Wear ear protectors!
Vibration information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Sawing of metal
Vibration emission value a
..................................................
h
Uncertainty K= ......................................................................
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for diff erent
applications, with diff erent accessories or poorly maintained, the vibration emission may diff er. This may signifi cantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may signifi cantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the eff ects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
BAND SAW SAFETY INSTRUCTIONS
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord. Cutting
accessory contacting a „live" wire may make exposed metal
parts of the power tool „live" and could give the operator an
electric shock.
Wear ear protectors. Exposure to noise can cause hearing
loss.
ADDITIONAL SAFETY AND WORKING INSTRUCTIONS
Use protective equipment. Always wear safety glasses when
working with the machine. The use of protective clothing is
recommended, such as dust mask, protective gloves, sturdy
non-slip footwear, helmet and ear defenders.
The dust produced when using this tool may be harmful to
health. Do not inhale the dust. Wear a suitable dust
protection mask.
Do not machine any materials that present a danger to
health (e.g. asbestos).
Switch the device off immediately if the insertion tool stalls!
Do not switch the device on again while the insertion tool is
stalled, as doing so could trigger a sudden recoil with a high
reactive force. Determine why the insertion tool stalled and
rectify this, paying heed to the safety instructions.
The possible causes may be:
• it is tilted in the workpiece to be machined
• it has pierced through the material to be machined
• the power tool is overloaded
Do not reach into the machine while it is running.
20
ENGLISH
BS 125 (220 V - 240 V)
BS 125 (110 V - 120 V)
..................... 4482 46 03... ........................... 4482 56 03...
...000001-999999
...000001-999999
....................... 1100 W .....................................1100 W
...................... 0-116 m/min ............................. 0-116 m/min
.1139,8 x 12,7 x 0,5 mm ........... 1139,8 x 12,7 x 0,5 mm
............... 125 x 125 mm ......................... 125 x 125 mm
......................ø 125 mm ................................ ø 125 mm
..........................6,5 kg ....................................... 6,5 kg
...........................90 dB (A) .............................. 90,2 dB (A)
.........................101 dB (A) ............................ 101,2 dB (A)
........................1,09 m/s
2
.................................. 1,27 m/s
..........................1,5 m/s
.................................... 1,5 m/s
2
The insertion tool may become hot during use.
WARNING! Danger of burns
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the machine
is running.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
Clamp your workpiece with a clamping device. Unclamped
workpieces can cause severe injury and damage.
Always disconnect the plug from the socket before carrying
out any work on the machine.
Do not use cracked or distorted saw blades.
Always place the guide shoe on the workpiece when
sawing.
Do not start the blade when in contact with workpiece. Wait
for blade to reach full speed before beginning cut.
When blade is binding, or when interrupting a cut for any
reason, release the trigger and hold the cutter motionless in
the material until the blade comes to a complete stop. Never
restart the machine when the blade in contact with
workpiece.
SPECIFIED CONDITIONS OF USE
The Band Saw cuts lengthways and mitre accurately in
diff erent type of metals such as metal profi les (UniStrut),
pipes, metal studs, channels, aluminium profi les, metal
sheets.
Do not use this product in any other way as stated for
normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product
described under "Technical Data" fulfi lls all the relevant
regulations and the directives 2011/65/EU (RoHs), 2014/30/
EU, 2006/42/EC, and the following harmonized standards
have been used:
EN 60745-1:2009 + A11:2010
EN 60745-2-20:2009
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61547:2009
EN 55015:2013
EN 50581:2012
Winnenden, 2017-11-30
2
Alexander Krug
2
Managing Director
Authorized to compile the technical fi le.
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
MAINS CONNECTION
Appliances used at many diff erent locations including wet
room and open air must be connected via a residual current
device (FI, RCD, PRCD) of 30mA or less.
Connect only to single-phase AC current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
Make sure the machine is switched off before plugging in.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
If the supply cord of this appliance is damaged, it must only
be replaced by a repair shop appointed by the manufacturer,
to avoid hazardous situations
Use only Milwaukee accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our Milwaukee service
agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket
before carrying out any work on the machine.
Please read the instructions carefully before
starting the machine.
Keep hands away from rotating parts.
Always wear goggles when using the machine.
Wear gloves!
Do not dispose of electric tools together with
household waste material.
Electric tools and electronic equipment that
have reached the end of their life must be
collected separately and returned to an
environmentally compatible recycling facility.
Check with your local authority or retailer for
recycling advice and collection point.
Class II tool, tool in which protection against
electric shock does not rely on basic insulation
only, but in which additional safety precautions,
such as double insulation or reinforced
insulation, are provided.
There being no provision for protective earthing
or reliance upon installation conditions.
European Conformity Mark
National mark of conformity Ukraine
EurAsian Conformity Mark.