ELECTRICAL INSTALLATION
ADDITIONAL CABLE FUSE (NOT INCLUDED)
4
Install an extra fuse (not included) for the +12V power cable near the battery to secure the power
cable. The distance between the fuse and the battery should not exceed 30 cm. The fuse size must be
adapted to the cable cross-section of the installed power cable (see table below).
Note: The fuse on the battery does not protect the amplifier, but the cable between the battery and the
amplifier against short circuits.
0 - 20
20 - 35
35 - 50
50 - 65
65 - 85
85 - 105
105 - 125
Recommended minimum cable cross-section to guarantee full amplifier performance:
Up to a length of 3 m: 25 mm
From a length of 3 m: 35 mm
CAUTION
The amplifier has internal device fuses located on the internal circuit board. If you suspect these
are defective, you will need to remove the bottom panel of the amplifier. Check the fuses for a
defect by pulling out the fuses with suitable pliers in order to replace them if necessary.
Only replace defective fuses with new ones that are of the same type and have the same fuse
rating.
0 - 1,2
1,2 - 2,1
2,5
4
4
6
6
10
10
10
16
16
16
16
20
20
2
2
Cable length in meters
2,1 - 3,1
3,1 - 4,0
4
6
10
10
10
16
16
20
20
20
20
35
20
35
Minimum cable cross-section in mm
4,0 - 4,9
4,9 - 5,8
6
10
16
16
16
20
20
20
35
35
35
35
35
50
2
ENGLISH
5,8 - 6,7
6,7 - 8,5
10
10
16
20
20
20
20
35
35
50
35
50
50
50