2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Rundown Error Detection
[Functional overview]
If the tool shuts off before the set time has passed since work started, this will be judged
NOK.
[Default value]
*0.0 s
[Setting value]
*0.0 s to 3.0 s
Retightening Prevention
[Functional overview]
Unless the selected time has passed since work was complete, the tool will not operate
even if the trigger is on.
[Default value]
*0.0 s
[Setting value]
*0.0 s to 3.0 s
Cross Thread Reduction
[Functional overview]
This is a tool operation option for reducing cross threading.
OFF:
Soft Start Up Shift Timing: The no-load speed is fixed at
360 degree Reverse:
[Default value]
OFF (Soft Start Up Shift Timing *0.0 s)
[Setting value]
OFF, Soft Start Up Shift Timing (*0.0 to 1.0 s), 360 degree Reverse
Entering the value with (*) will disable the function.
EN
Cross threading reduction function disabled.
the set time has passed since work started.
the tool lowest rpm: about 350 rpm
In order to follow a thread, the tool operates 360 degrees
reversely before operating forward.
- 64 -