Manual
Installation:
After receiving the complete SPC package, please check for damage caused by transport and check the
contents of the package. Never install the SPC near wet conditions and make sure the power is switched
off. Only authorized personnel are allowed to install the SPC and to take care of technical malfunctions.
Usage:
Main switch on "AUTO":
Main switch on "0":
Main switch on "100%":
Set-up:
Knob 1 will set the minimal ventilation level (f.e. 20%)
Knob 2 will set the maximum ventilation level (f.e. 80%)
Knob 3 will set the ventilation bandwidth. Irrespective to the min. and max. settings, getting below
10% bandwidth is not possible (f.e. 2ᵒC)
Knob 4 will set the desired temperature. When the air temperature exceeds your desired
Temperature, the fans will automatically adjust their speed.
- Accurate climate control
- Adjustable minimum and maximum engine RPM
- 6 feet cable with temperature sensor included
- Easy installation an usage
- IP44 protection approved (damp-proof)
Attention:
The SPC's are being programmed for most used fans. However, switching the minimal speed down is possible.
For this purpose turn the cal. Min potentiometer (under the socket template on the left hand side). Turn left for
minus and right for plus. Turn down the speed in such a manner that the fan will always keep running.
TURNING DOWN ANY MORE WILL INCREASE THE POSSIBILITY OF HUMMING FANS. If the SPC is being
switched off through the switch (0-position) and then is restarted, first put the switch on 100% and only
afterwards on auto. This is being recommended in order to protect the connected fans.
Technical Specifications
Adjustable capacity
Input
Frequency
Dynamic range
Temperature sensor
Bandwidth range
7A | 14A | 28A
7A | 14A | 28A
Temperature
Sensor 500cm
The SPC is now fully automatic. Depending on your configuration, the fans
are controlled automatically. When the SPC is turn on, the fans will always
run at full speed for a few seconds,
The SPC is turned 'OFF'.
In case of automatic malfunction, use this option in order to run the fans at full speed.
SPC 7 Amp
Max. 8 Amp
220V – 240V
50/60 Hz
0.5 - 8.0 Amp
4K7 at 25ᵒC
1 ~ 7 ᵒC
SPC
4
Fuse
Zekering
Sicherung
Switch
1
2 3
Schakelaar
Schalter
Fan Air
Fan Air
In / Out
In / Out
SPC 14 Amp
Max. 16 Amp
220V – 240V
50/60 Hz
0.5 – 16.0 Ampe
4K7 at 25ᵒC
1 ~ 7 ᵒC
SPC 28 Amp
Max. 2x 16 Amp
220V – 240V
50/60 Hz
2 x 0.5 -16.0 Amp
4K7 at 25ᵒC
1 ~ 7 ᵒC