Herunterladen Diese Seite drucken

SOMFY Sonesse 30 RS485 Anleitung Seite 10

Vorschau ausblenden Andere Handbücher für Sonesse 30 RS485:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
EN
Observations
The motorised
product is
noisy.
The motorised
product stops
too soon or
too late.
10
Possible causes
An incorrect Data cable has
been used
End-limits are not properly
adjusted.
The wheel and the crown are
not adapted to the used tube.
The mechanical plays between
drive, accessories, tube and end
of tube are too high.
The wheel is not properly fixed
to the tube.
The equipment is constrained
between the brackets.
The length of the notch is not
adapted to the drive hook or to
the used crown.
Debris, screws or other are in
the tube.
The temperature of the
environment is not in
conformity with the operating
temperature.
The end limits of the motorised
product slip.
The motorised product does
not fall within the
recommended weight limits.
Copyright
Check the Data cable.
Adjust the end-limits.
Change the wheel and the crown.
The mechanical plays between
drive, accessories, tube and end
of tube must be decreased to the
minimum.
Fix the wheel properly to the tube.
Decrease the constraint between
the brackets.
Adapt the length of the notch to
the drive hook or to the used
crown.
Empty the tube.
Change the environment
temperature.
Re-set the end limits.
Check the compatibility of the
motorised product. Consult a
Somfy contact or visit
www.somfy.com.
©
2022 SOMFY ACTIVITES SA. All rights reserved.
Sonesse 30 RS485
Solutions

Werbung

loading