G
B
out with a total delay between the two gate leaves. Therefore, first the leaf M2 will close
completely; once it is OFF, M1 will start closing. This separate movement of the two gate leaves
is done to avoid their incorrect overlapping.
TECHNICAL SPECIFICATIONS
- Temperature range
- Humidity
- Voltage
- Frequency
- Battery power
- Transformer Power
- Maximum absorption
- Power supply microinterruptions
- Maximum power SIGNAL output
- Maximum blinker power
- Power for photocells and accessories 1 A ± 15 %
- Power for radio connector
RADIO SPECIFICATIONS (model B2D 24V-CRX)
- Reception frequency
- Impedence
- Sensitivity
- Feedback control
- Memory storage (codes)
- All inputs must be used as clean contacts because the power is generated internally (secure
power) to the board and is set up to ensure compliance with double or reinforced insulation
with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in such
a manner as to ensure compliance with double or reinforced insulation with regard to
dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check every
time it starts operating.
MAINTENANCE
To be undertaken by specialized staff after disconnecting power supply.
Make certain that moving parts located inside the box are greased once a year, and check the
force transmitted through the drive to the gate.
In the event that the need for servicing or repairs should arise, the speed reducer can be
removed from the box without taking down the gate.
- Lift the cover from the box, isolate the motor from the power supply by disconnecting the
cable, then remove the curved lever: the gate can now swing freely.
- Then unscrew the for nuts that fix the motor.
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned
the gate in intermediate position, check the correct ignition of red LEDS DL6, DL7, DL8, DL9
and DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the following
and replace any faulty components.
DL6
OFF Stop button malfunction (if Stop is not connected, perform the jump
between COM A+ and STOP).
DL7 or DL8 OFF Faulty photocells (In case the edge is not connected, carry out jumper
between COM A+ and PHOTO 1/PHOTO 2)
DL9 or DL10 OFF Faulty safety edge (In case the edge is not connected, carry out jumper
between COM A+ and EDGE 1/EDGE 2)
During functioning with personnel present, with DIP 1 to ON, check that during opening of M1
and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the red DL3
and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
DL13 blue
ON Some functions are enabled via smartphone, so via smartphone check the
card functions as the dips/trimmers status may not be true.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and
insert them one at a time in order to more easily identify the cause of the fault.
0 ÷ 55 °C
< 95 % without condensation
230 V~ ± 10% (120 V 60 Hz upon request)
50/60 Hz
20-24 Vdc
130 VA - 230 Vac / 18 Vac
25 mA
100 ms
24 Vdc 3 W (equivalent to one 3W or 5 LED light bulb
with resistor in series at 2.2 K Ω)
24 Vdc 20 W
200 mA
433,92 MHz
52 Ω
>1 µV
PLL
1000
40