6. USAGE
6.1. PARTS OF THE FILTER AND THEIR RECOMMENDED CHANGE OUT RATES
Stage of filtration
First, second, third
Fourth
Fifth, sixth
To purchase replacement components, visit www.ecosoft.com
* This reverse osmosis system contains a replaceable component critical to the efficiency of the system. Replacement
of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to
ensure the same efficiency and contaminant reduction performance.
6.2. THE PROCEDURE FOR REPLACING PRE-FILTER CARTRIDGES
5
1.
Shut off feed valve
2.
Wash your hands with antibacterial soap.
3.
Unscrew with the sump wrench 10 first and second sumps in water flow
direction (right to left). Be careful as the sumps are filled with water.
4.
Remove the used filter cartridges.
5.
Wash sumps with unflavored soap and a clean sponge, then rinse
thoroughly with water.
6.
Insert the new cartridges in the first and second sumps by water flow
direction.
7.
Disconnect the tube stemming from the third sump from the auto
shut-off valve.
8.
Open the feed valve
coal dust that may be produced in cartridges during shipping.
CAUTION! This water will pour through the tube disconnected from auto shut-off valve, prepare a vessel to
collect it.
Code P0090636 - Rev 0 - 19/06/2019
Name of cartridge
Pre-filters for reverse osmosis
Reverse osmosis membrane*
Pre-filters for reverse osmosis
6
and tank valve
.
5
and let through the first two installed cartridges 5-7 liters (1.5-2 Gallons) of water to rinse the
Term for replacement
Once in 3 month for all models of reverse
osmosis systems, axcept models with AquaGreen
technology.
Once in 6 month for models with AquaGreen
technology
Once a year
Once in 6 month
47