Spezifikationen
pe set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5}"
linesensor {line_num} {energy_sensor} events ty-
pe show
linesensor {line_num} {energy_sensor} maxval set
{float}
linesensor {line_num} {energy_sensor} maxval
show
linesensor {line_num} {energy_sensor} minval set
{float}
linesensor {line_num} {energy_sensor} minval
show
linesensor {line_num} {energy_sensor} hyst set
{float}
linesensor {line_num} {energy_sensor} hyst show shows hysterese value for line meter
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
linesensor {line_num} events set {OFF=0|ON=1}
linesensor {line_num} events show
linesensor {line_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5}"
linesensor {line_num} events type show
linesensor {line_num} maxval set {float}
linesensor {line_num} maxval show
linesensor {line_num} minval set {float}
linesensor {line_num} minval show
linesensor {line_num} hyst set {float}
linesensor {line_num} hyst show
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
port set {port_num}
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
port show
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state set {OFF=0|ON=1|DISABLED=2}
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state show
linesensor beeper set {OFF=0|ON=1}
linesensor beeper show
modbus
modbus enabled set <off=0/on=1>
modbus enabled show
modbus port set <ip_port>
modbus port show
port
port {port_num} state set {OFF=0|ON=1}
port {port_num} state show
port all state set "{port_list}" {OFF=0|ON=1}
port all state {MODE0=0|MODE1=1|MODE2=2}
show
port {port_num} reset
port {port_num} toggle
port {port_num} batch set {OFF=0|ON=1} wait
{num_secs} {OFF=0|ON=1}
port {port_num} batch cancel
port {port_num} label set "{name}"
Expert Power Control 8031/8035
shows what event types are enabled
sets maximum value for line meter
shows maximum value for line meter
sets minimum value for line meter
shows minimum value for line meter
sets hysterese value for line meter
sets Port for Power Port Switching actions
shows Port for Power Port Switching actions
sets Port state for Power Port Switching actions
shows Port state for Power Port Switching actions
LEGACY - enables events on/off
LEGACY - shows if events are enabled
LEGACY - enables different event types
LEGACY - shows what event types are enabled
LEGACY - sets maximum value for line meter
LEGACY - shows maximum value for line meter
LEGACY - sets minimum value for line meter
LEGACY - shows minimum value for line meter
LEGACY - sets hysterese value for line meter
LEGACY - shows hysterese value for line meter
LEGACY - sets Port for Power Port Switching acti-
ons
LEGACY - shows Port for Power Port Switching
actions
LEGACY - sets Port state for Power Port Swit-
ching actions
LEGACY - shows Port state for Power Port Swit-
ching actions
enables beeper for line meter alarms
shows if beeper for line meter alarms is enabled
enters cmd group "modbus"
enables Modbus TCP support
shows if Modbus is enabled
sets Modbus TCP port
shows Modbus TCP port
enters cmd group "port"
sets port to new state
shows port state
sets several ports in one cmd - e.g. port all state
set "1,3,5" 1
shows all port states in 3 different view modes
start reset sequence for port
toggles port
starts batch mode for port
cancels batch mode
sets port label name
L
L
L
L
L
L
L
L
L
L
L
L
L
L
4
68