Visual inspection of load- bearimg parts
A
B
C
D
Controls check
Check that the Emergency Stop is pulled out and switch Ascender on. Wait for full activation of the Ascender (LED turns green)
Move the Throttle in both directions and ensure that Rope Grab turns smoothly in both directions
Check that the emergency descent is working correctly. The lever should return to neutral position when released
Push the Emergency Stop and check that the Ascender is switched off and cannot be activated by Power Button
38
Rope Guide (A)
Check Rope Guide for obvious damage, deformation or sharp edges. Rope Guide should not be bent and must fit
neatly with the Rope Cover. Check wear indicator, this should be completely intact.
Rope Cover
Check the Rope Cover function by opening and closing it. During closing the Rope Cover must lock unhindered
into its position. Check the Rope Cover further for deformation, excessive wear or any sharp edges.
Rope Wedge (B)
Check Rope Wedge for deformation or any visible damage. The Rope Wedge should be straight, sit just above
the bottom of the Rope Grab and should not touch the ribs on the inside of the Rope Grab.
Rope Grab (C)
Check that Rope Grab is clean and not filled with dirt, sand, paint or any other foreign material. Check the inside
for obvious damage, signs of wear or sharp edges.
Connection Sling and Carabiner (D)
Check Connection Sling for wear, discoloration or damage such as cuts, abrasion and contaminants (paint,
glues, chemicals). Take particular note of the condition of the Titanium Sling Bolt and Carabiner Loop. Inspect
the carabiner for wear, damage and deformation. Check that the Carabiner opens and locks correctly.