Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning - Hazet 9033 N-6 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Press the operating lever to operate the tool.
• Release the operating lever to stop the tool.
• Please note that the tool still carries on
running after the operating lever has been
released.
• After completing the operation, switch off
the compressor and store it in accordance
with the operating instructions of the com-
pressor.
• Only use clean and dry air at a max. pressure
of approx. 90 PSI or 6.2 bar. Dust, flamma-
ble vapour and high humidity can result in
damage to the pneumatic tool's motor.
• Do not remove any stickers and replace
damaged stickers.
• Keep hands, loose clothing and long hair
away from the tool's moving part.

5. Maintenance and cleaning

• Lubrication:
Pneumatic tools have to be lubrica-
ted throughout their entire service life.
The motor and the ball bearings require
compressed air to operate the tool. Since
the moisture in the compressed air corrodes
the motor, the motor must be lubricated
every day. We recommend that an integra-
ted lubricator is used to do this.
• HAZET 9070 N-1 lubricator for mounting to
the pneumatic tool.
• Lubricating the pneumatic motor by
hand:
Disconnect tool from the air supply and
hold with the air inlet pointing upwards. Put
1 or 2 drops of special pneumatic oil into
the air inlet.
Connect the tool to the compressed air
supply; cover the air outlet on the tool with
a towel and operate for a few seconds.
Never use combustible or easily evaporable
liquids such as kerosene, diesel or petrol to
lubricate the tool.
20
3
Design and function
Immer persönliche Schutzausrüstung tragen!
Always wear personal protective equipment!
^ hazet.com • ] info@hazet.de
^ hazet.com • ] info@hazet.de
ATTENTION!
Excess oil in the motor will be
immediately expelled through the air
outlet.
WARNING!
Never point the opening of the outlet
at any person or object. The air outlet
is located at the back of the handle.
• Maintenance
Always disconnect the device from the
compressed air supply prior to carrying out
maintenance work.
• If used daily, carry out maintenance every
3 months, or every 1000 operating hours at
the latest.
• Damaged or worn components such as
o-rings and bearings etc. must be replaced
and all moving parts must be lubricated.
• Only use spare parts recommended by the
manufacturer, as any other parts will invali-
date the warranty.
• Ensure that the relevant environmental pro-
tection regulations are observed when dis-
posing of the components, lubricants and
oils, etc.
• For tool cleaning or cleaning of its compon-
ents we recommend using white spirit.
• Never clean with solvents or acids, esters
(organic compounds comprising acids
and alcohol), acetone (ketone), chlorinated
hydrocarbons or oils containing nitro hydro-
carbons. Do not use any chemicals with a
low burning point.
• For customer service, please contact your
distributor or the HAZET Service Centre.
6. Malfunctions
If malfunctions occur, check the following:
• Compression system and compressed air
supply line, air consumption l/min and hose
diameter according to the technical data of
the tool
• Check the compressed air for the occurrence
of dust, condensate and rust particles
• Excess lubrication of the air motor

Werbung

Inhaltsverzeichnis
loading