INTRODUCING JBC TECHNOLOGY
The exclusive JBC heating system achieves an
exceptional thermal recovery, which increases
productivity, quality, reduces cost of ownership and
ensures fast return on investment.
Unequalled thermal response
An excellent soldering tool features instant thermal
response conceived by a high power/mass ratio.
A high power/mass ratio is being used to maintain
the tip's temperature as close as possible to the one
selected on the control unit, even when the thermal
load is significant. This is the formula needed to
perform high quality solderjoints and avoid cold
ones, protect the PCB that is being soldered and
increase productivity.
INTELLIGENT HEAT MANAGEMENT
The only time that a soldering tool should be at
working temperature is when it is actually being
used. JBC stations identify if and how a tool is being
used and depending on this switches the tool to
one of the following modes with their respective
temperatures:
Work mode: selected working temperature i.e.
350°C.
Sleep mode: during short periods of inactivity
the tool's temperature is being lowered to an
intermediate temperature i.e. 220°C.
Hibernation mode: During larger periods of
inactivity i.e. 30 minutes, the tool's power is being
cut off and it cools down to room temperature.
The advantages of this heat management are
significantly increased catridge lifespan and
substantial energy savings which ensures low cost
of ownership.
JBC Tools save money by managing Heat
efficiently saving energy,time and improving
processes.
If you would like to change the SLEEP and
HIBERNATION parameters, as any other function,
see page 11.
Technical specifications
- Temperature selection from 90 to 450°C or 190
to 840ºF (±5%).
- Power: 75W.
- Safety transformer, mains separator and double
isolation, with integrated temperature protection
fuse.
- MT 2920 230V control unit
Input: 230V 50Hz. Output: 24V
- MT 2920 120V control unit
Input: 120V 60Hz. Output: 24V
- MT 2920 100V control unit
Input: 100V 60Hz. Output: 24V
- Total weight of unit: 2.6 Kgs (6,5lbs).
- ESD protected housing.
Typical surface resistance: 10
square.
- Complies with CE standards on electrical safety,
electromagnetic compatibility and antistatic
protection.
- RoHS compliant.
- Equipotential connector and the tool tip are
connected to station mains ground supply for
ESD protection.
This product should not be thrown in the
garbage.
You will find all the information about control unit
MT 2920 in the following link:
http://www.jbc.es/english/catalog
JBC reserves the right to make technical changes without prior
notification.
2
ENGLISH
Ref. 2920200
Ref. 2920100
Ref. 2920109
-10
Ohms/
5
11

Werbung

loading

Diese Anleitung auch für:

292020029201002920109