Herunterladen Inhalt Inhalt Diese Seite drucken

Enerpac TS Serie Gebrauchsanweisung Seite 2

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
bends and kinks will internally damage the
hose leading to premature hose failure.
Do not drop heavy objects on
hose. A sharp impact may cause
internal damage to hose wire
strands. Applying pressure to a
damaged hose may cause it to rupture.
IMPORTANT: Do not lift hydraulic
equipment by the hoses or swivel
couplers. Use the carrying handle or
other means of safe transport.
CAUTION:
equipment away from flames and
heat. Excessive heat will soften
packings and seals, resulting in fluid leaks.
Heat also weakens hose materials and
packings. For optimum performance do not
expose equipment to temperatures of 65°C
[150°F]
or
higher.
cylinders from weld spatter.
DANGER:
pressurized hoses. Escaping oil
under pressure can penetrate the
skin, causing serious injury. If oil is injected
under the skin, see a doctor immediately.
WARNING:
cylinders in a coupled system.
Never
unconnected
cylinder becomes extremely overloaded,
components can fail catastrophically causing
severe personal injury.
IMPORTANT: Hydraulic equipment
must only be serviced by a qualified
hydraulic technician. For repair
service, contact the Authorized ENERPAC
Service Center in your area. To protect your
warranty, use only ENERPAC oil.
WARNING: Immediately replace
worn or damaged parts by genuine
ENERPAC parts. Standard grade
parts will break causing personal injury and
property damage. ENERPAC parts are
designed to fit properly and withstand high
loads.
Keep
hydraulic
Protect
hoses
Do
not
Only
use
hydraulic
use
a
cylinder
couplers.
3.O PRODUCT DESCRIPTION
TS & TD cylinders have a fully threaded
body for maximum mounting flexibility. The
maximum operating pressure is 5000 psi
[350 bar] (35MPa). MS cylinders have a
threaded body with a hexagonal flange for
manifold and/or fixture mounting. The
maximum operating pressure is 5000 psi
[350 bar] (35MPa).
TS-models
return. The oil port is located in the bottom
of the cylinder. TD-models are double
acting, hydraulic return. The oil ports are
located in the bottom of the cylinder. Oil
port specifications are identified by model
number (see Table A).
single-acting, spring return. A seal is
and
included with all MS style cylinders, which
must be installed and positioned between
handle
the cylinder and the manifold for proper
sealing and installation. (See illustration 4)
4.0 APPLICATION
These cylinders are designed to position
and clamp workpieces in workholding
with
fixtures. Because of the compact design
If
the
they are ideal for mounting in confined
areas.
5.0 INSTALLATION
warnings, before starting to operate any of
the equipment. In case of doubt contact
Enerpac.
withstand the operating pressure of 5000 psi
[350 bar] (35 MPa).
exceed the safety limits of the lowest rated
component within your hydraulic system.
2
are
single-acting,
IMPORTANT: It is mandatory that
the
operator
understanding of all instructions,
safety regulations, cautions and
WARNING: To avoid personal injury
and possible equipment damage
make sure the manifold or fixture,
all fittings and piping are able to
WARNING: Use hydraulic gauges to
indicate safe operating pressures in
each hydraulic system. Do not
spring
MS-models are
has
a
full

Werbung

Inhaltsverzeichnis
loading