Herunterladen Diese Seite drucken

Pepperl+Fuchs I HH20 Serie Kurzanleitung Seite 41

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

HANDHELD I*-HH20*
Operation
4.
Press the CLEAR input key (
You can only delete the last character entered, not individual characters
within the character string.
5.
Press the left softkey (
If the character entered does not correspond with the syntax of the data
format, a fault indication is issued and the value is not accepted.
6.
Position the read/write head on the handheld directly beside the data
carrier.
7.
Press the left softkey (
carrier.
If the write process is successful, "OK" appears on the display and the
status LED flashes green. If you have activated the buzzer and the
vibration alarm in the Settings menu, an acoustic signal sounds and the
handheld vibrates. If the transfer was unsuccessful, the status LED briefly
flashes red and a fault indication is issued.
Note!
Observe the input format
Data bytes in hexadecimal data format must always contain 2 characters and
data bytes in decimal data format must contain 3 characters.
) to delete individual characters.
) to confirm your entry.
) to write the data to the data
EN