4.4 Set advanced parameters
Установка дополнительных параметров.
With the controller you can control the compressor and the dryer fan as well as calibrate
the operating parameters. In case of special operational control requirements, the user can
change the values of the programmed parameters. Press and hold the button
seconds. Enter password.
Designation
Description
PS
Password
/2
Measurement
/3
Number of hours for Ecd
/4
Selection of the displayed sensor
/5
Choice 0=˚C and 1=˚F
/6
Disable decimal point
/С1
Sensor calibration 1
/С2
Sensor calibration 2
Stl
Setting the minimum dew point (ECO
mode)
StH
Setting the maximum dew point (ECO
mode)
L1
Low dew point alarm threshold with
compressor off
L2
Low dew point alarm threshold with
compressor on
r5
Lower display limit (sensor1)
r6
Upper display limit (sensor1)
tE
Operating time in ECO mode
tE1
Minimum ECO operating time
tL
Time delay for low dew point alarm
С0
Compressor and fan start delay
COMPRAG RDX series compressed air refrigerated dryer
ATTENTION! Contact your local dealer for a password to change
system parameters. It is forbidden to change the factory settings
without any apparent reason!
Range
Unit
measurements
1-200
___
1-15
___
1-24
___
1-3
___
0;1
___
0;1
___
+-12,7
˚С
+-12,7
˚С
-2;100
˚С
0-100
˚С
-50;200
˚С
-50;200
˚С
-2; r6
˚С
r5;200
˚С
1-199
sec
1-199
min
0-90
sec
0-200
min
within 3
Chief
settings
22
4
8
1
0
0
0
0
0
15
2
-2
3
7
60
6
65
1
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

24-360

Inhaltsverzeichnis