6.7: Tempil stick 274°C is melting
Possible cause
Fusion temperature set to too
high value
Fusion device damaged
7.2: Not possible to correctly mount centering aid for the jacket pipe and
locking pin is not in end position
Possible cause
Strap is routed towards the inside
of the base plate, blocking the
correct fit of the centering aid
Locking pin dirty
7.3; 7.12: Not possible to connect the drilling adapter with the COOL-FIT
hole saw
Possible cause
Chips and foam residues block the
adaptor
PE pipe piece is blocking the hole
saw
7.10; 8.5: Not possible to correctly mount the centering aid for the inner
pipe on the base plate and the locking pin is not in end position
Possible cause
Guiding sleeve touches inner pipe
Locking pin dirty
Solution
Set fusion temperature to 255°C
Contact GF
Solution
Mount base plate again and route straps
towards the outside of the base plate
Clean locking pin with compressed air or
vaccum cleaner
Solution
Clean the adaptor with compressed air or
vaccum cleaner
Remove the PE pipe piece on using the hexagon
socket allen key
Solution
Turn guiding sleeves counterclockwise for a
few turns
Clean locking pin with compressed air or
vaccum cleaner
EN