 First, check whether the power cable is inserted at the light source and in a working power socket.
 Ensure the light source is switched on.
No light
Cause
Defective bulb:
Defective fuse:
Thermal protector has responded:
Defective lamp socket:
Defective switched-mode power supply:
Insufficient light
Cause
Bulb remains at the minimum setting (dimmed) de-
spite moving the electrical brightness knob:
Fan failure:
Note: A defective bulb can also cause a fan standstill or a speed reduction.
Use only original spare parts! If this is not done, it can lead to personal injury and material dam-
age. Repairs that are not described in this document must only be carried out by authorized
workshops!
Before opening the device, always pull the power plug!
Do not touch the quartz envelope or the inside of the lamp reflector! This drastically shortens the
life of the bulb. Grasp the bulb only at the outside of the reflector or close to the contact pins. Al-
ways let hot bulbs and their environment cool off sufficiently.
ma 1100-1200-1300$24.docx
TROUBLESHOOTING
Fault elimination
Replace bulb
Replace primary circuit fuse.
Keep air vents clear, instrument restarts after a
short time.
Replace lamp socket
Return device for repair
Fault removal
Return device for repair
Return device for repair