1 Replacement instructions for the PURITY Quell ST
Before replacing the filter, please read the system manual for the PURITY Quell ST filter system.
There you will find detailed information on the operating and safety instructions, maintenance,
troubleshooting and technical data.
2 Liability exclusion
The filter must be replaced exactly in accordance with the information in these replacement instructions.
BRITA shall not be liable for any damage, including consequential damage, that may occur as a result
of not observing these replacement instructions or carrying them out incorrectly.
3 Product-specific safety instructions
For hygiene reasons, the filter material of the cartridge is subjected to a special treatment with silver.
A small amount of silver, that is not harmful to health, may leach into the water. This is in accordance
with the recommendations of the World Health Organisation (WHO) for drinking water.
Note for people with kidney disease or dialysis patients: during the filter process there may be a slight
increase in the potassium content. Should you suffer from kidney disease and/or must keep to a special
potassium diet, we recommend that you consult your doctor first.
4 Replacing the filter cartridge
Caution: During the exchange, carefully examine all dismantled parts! Faulty parts must be
!
replaced and dirty parts cleaned. Before replacing parts read the operating and safety instructions
(Manual Chapter 3). After storage and transportation at under 0 °C the product must be stored in its
original packaging, open, for at least 24 hours before commissioning when it is to be operated under
the ambient temperatures specified in the "Technical data" table.
Filter systems without a measuring and display unit
The filter cartridge must be replaced after 6–12 months, but no later than 12 months after commis-
EN
sioning, regardless of the level of exhaustion of the filter system. If the capacity of the filter cartridge
has already been exhausted (Manual Chapter 7), it must be replaced earlier.
Filter systems with a measuring and display unit
The filter cartridge must be replaced no more than 12 months after commissioning regardless of the
level of exhaustion of the filter system. If the capacity of the filter cartridge has already been
exhausted (Manual Chapters 5 and 7) it must be replaced earlier. If the capacity of the cartridge
is exceeded, this will appear in the display as negative and flashing. No more bars will be shown in
the bar display. If the monthly limit for the cartridge is exceeded, the date will flash to indicate this.