4.2 Carbon filters
Conventional carbon filters cannot be cleaned. The capacity of these filters is
limited. You can use such filters for about 3-6 months. Replace a depleted filter.
Find further information on the filter packaging.
4.3 Replacing of the illuminant
1.
WARNING! Disconnect the appliance from the energy supply.
2. Let the illuminant cool down before replacing.
3. Remove the grease filters and push out the illuminant. Be especially careful
while doing so.
4. Pull the illuminant carefully out of the hole and
disconnect the energy supply wire.
5. Now connect the new illuminant to the energy
supply wire.
6. Push the wires back into the hole and fix the new
illuminant.
5. Trouble shooting
POSSIBLE CAUSE
The plug of the appliance is not
connected to the socket.
The plug has become loose.
The socket is not supplied with
energy.
The fuse is switched off.
All manuals and user guides at all-guidesbox.com
MALFUNCTION
The appliance does not work at all.
Light is on but motor does not work.
32
MEASURE
Check the corresponding socket by
connecting it with another appliance.
Check the fuse.
The voltage is too low. Compare the
data on the model plate with the data
of your energy supplier.