GP-MPPT-100/30
A
NOTICE! Damage hazard
Allow at least 5 cm of space around the controller for proper cooling.
I
NOTE
Mount the controller as close to the battery as possible.
I
NOTE
The controller is designed to be mounted vertically.
1. Drill 4 holes.
2. Mount the controller with appropriate fasteners.
6.2 Choosing proper wires and fuses
A
NOTICE! Damage hazard
For proper operation of the charging system, choose the size of wires between the
solar panel and the battery carefully.
A
NOTICE! Damage hazard
Do not exceed wire length of 7.6 m from solar panel to the battery.
Solar panel
50 W
80 W
100 W
160 W
200 W
300 W
400 W
A
NOTICE! Damage hazard
Install an in-line fuse as close to the positive battery terminal as possible. This installation
prevents any damage to the connected devices in case of excessive current.
EN
Gauge
#14 AWG - 1.6 mm
#12 AWG - 2 mm
#10 AWG - 2.6 mm
#10 AWG - 2.6 mm
#10 AWG - 2.6 mm
#8 AWG - 3.3 mm
#8 AWG - 3.3 mm