15. Circulation Liquid
Set circulation of heating water.
There are 2 types of settings, water and glycol.
(NOTE) Please set glycol when using anti-freeze liquid.
It may cause error if setting is wrong.
16. Heat-Cool SW
Initial setting: Disable
Able to switch (fi x) heating & cooling by external switch.
(Open) : Fix at Heating (Heating +DHW)
(Short) : Fix at Cooling (Cooling +DHW)
(NOTE) This setting is disabled for model without Cooling.
(NOTE) Does not display if there is no Optional PCB.
Timer function cannot be used. Cannot use Auto mode.
17. Force Heater
Initial setting: Manual
Under manual mode, user can turn on force heater through quick menu.
If selection is 'auto', force heater mode will turn automatically if pop up error
happen during operation.
Force heater will operate follow the latest mode selection, mode selection is
disable under force heater operation.
Heater source will ON during force heater mode.
18. Defrost signal
Initial setting: No
Defrost signal sharing same terminal as bivalent contact in main board. When
defrost signal set to YES, bivalent connection reset to NO. Only one function can
be set between defrost signal and bivalent.
When defrost signal set to YES, during defrost operation is running at outdoor
unit defrost signal contact turn ON. Defrost signal contact turn OFF after defrost
operation end.
(Purpose of this contact output is to stop indoor fan coil or water pump during
defrost operation).
19. Pump fl owrate
Initial setting: T
If pump fl owrate setting is T, unit adjust pump duty to get different of water inlet
and outlet base on setting on * T for heating ON and * T for cooling ON in
operation setup menu during room side operation.
If pump fl owrate setting is set to Max. duty, unit will set the pump duty to the set
duty at *Pump maximum speed in service setup menu during room side operation.
Initial setting: Water
System setup
Demand control
SG ready
External compressor SW
Circulation liquid
Select
Confi rm
System setup
SG ready
External compressor SW
Circulation liquid
Heat-Cool SW
Select
Confi rm
System setup
External compressor SW
Circulation liquid
Heat-Cool SW
Force Heater
Select
Confi rm
System setup
Heat-Cool SW
Force heater
Force defrost
Defrost signal
Select
Confi rm
System setup
Force heater
Force defrost
Defrost signal
Pump fl owrate
Select
Confi rm
12:00am,Mon
12:00am,Mon
12:00am,Mon
12:00am,Mon
12:00am,Mon
27