e - 5
Tipping-over protection.
e - 6
Poor burning.
e - 7
Room temperature
above 32°C.
e - 8
Defective booster.
e - 9
Air filter dirty; or
Fuel pump dirty.
The heater has been in operation
continuously for a period of 65 hours
and has turned itself off automatically.
Out of fuel.
-- : --
+
Too little ventilation.
-- : --
+
Always contact your dealer for any malfunctioning not listed above and/or when
the error keeps occuring after taking the corrective measure as described above.

autOMatic DeactivatiOn

This heater is fitted with a safety system that ensures that it switches off
automatically after 65 hours continuous operation. The following will then appear
in the display:
. If desired, you can switch the heater on again by pressing
the
button L (see section D).
autOMatic cleaninG MODe
When the heater has been burning continuously for two hours at its highest
setting, the burner will automatically start an autoclean procedure. The display
will show the autocleaningcode cl:05 running back to cl:01. The procedure takes 5
minutes, during which the heater will burn at its lowest setting, while the burner
autocleans. When the burner is clean again, the heater will automatically switch
back to the highest setting again.
i
cHilDPROOf lOcK / PaRental cOntROl
The childproof lock can be used to prevent children accidentally changing the
heater settings. When the heater is burning and the childproof lock is on, the heater
can only be switched off. Other functions are blocked then. If the heater has already
been switched off, the childproof lock also prevents accidental ignition of the
heater. Activate the childproof lock by pressing the appropriate key M and holding
it down for more than 3 seconds. The KEY-LOCK indicator
information display (Fig. H), indicating that the childproof lock has been activated.
Switch off the childproof lock by pressing the key M and holding it down for more
than 3 seconds once again.
J
tHe cORRect use Of 'save'
The 'SAVE' function allows you to limit the temperature. When this function is
activated, the heater will automatically switch off, when the room temperature exceeds
the set temperature by 3°C. Subsequently, when the room temperature has dropped
again to the set temperature, the heater will automatically switch on again. Activate
the 'SAVE' setting by pressing the appropriate P key. The SAVE indicator light will
light up (Fig. I). Switch off the function by pressing the SAVE key once again.
4
8
Re-ignite the heater.
Contact your dealer.
If necessary,
re-ignite the heater.
Contact your dealer.
Clean filter.
Contact your dealer.
Switch the heater back on.
Refill removable tank.
Ventilate better.
will appear on the
H: When the
mark
appears, the
childproof lock has been
activated.
I: When the SAVE light
lights up, the heater will
automatically switch on
or off in order to remain
within a specified tem-
perature range.