Fixing the Frame/Chimney
Should it be necessary to adjust the height of the frame,
proceed as follows:
• Unfasten the metric screws joining the two opposite
parts that can be seen from the front;
• Adjust the height of the frame as required, then re-
place the screws removed as above, making sure that
you insert 2 of them close to the panel lock;
• Lift the frame, insert the slots onto the screws and
slide them until they lock;
• Tighten the two screws and insert the other two
screws provided.
• Take the telescopic chimney locking bracket 7.2, re-
move the film from the double sided adhesive and fix
it inside the frame so as to hold it more firmly.
Before final locking of the screws it is possible to make
small adjustments to the frame, making sure that the
screws do not come out of the adjustment slot.
• The Frame must be securely fastened both due to the
weight of the Hood and the stress caused by occa-
sional sideways pressure on the Appliance when in
position. When fastened, check that the base is stable
even when the Frame is subjected to bending.
• In all cases where the Ceiling is not sufficiently
strong at the point of suspension, the Installation
technician must strengthen it with suitable plates and
counterplates, anchored to structurally sound ele-
ments.
Ducted version air exhaust system Connection
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe using the pipe clamps 25 (not provided).
• Remove any activated charcoal filters.