5.2 Blitzschutz, Versorgungsspannung und Erdung
Notice for USA/Canada (UL Requirements)
When an external antenna or the device itself is located outdoor:
- The Ethernet-Port (RJ45) is considered a TNV-1 circuit (according IEC 60950-1).
Connected Ethernet circuits must fulfill TNV-1 requirements (SELV circuits are not sufficient).
- The device must be properly earthed at the chassis earthing terminal.
- The 12 – 24 V power supply lines of the device are considered a TNV-1 circuit. Connected
power supply circuits must fulfill TNV-1 requirements. The PS791-2AC power supply may be
connected directly to 100 – 240 C AC primary circuits. The 100 – 240 AC wiring system must
be conducted to conduits. This wiring system (including conduits) shall be secured before
installation of the product, for example by using an outlet box, according to NEC or CEC.
When the device is located indoor:
- The Ethernet Port (RJ45) is considered a SELV circuit (according IEC 60950-1). All
connected Ethernet circuits must fulfill SELV requirements and shall be entirely contained
within a single low-voltage power distribution and within a single building.
- Do not connect any external LAN-circuit, powersupply or antenna coming from outdoor.
EXPLOSIONSGEFAHR
In einer leicht entzündlichen oder brennbaren Umgebung dürfen keine Leitungen an das
Gerät angeschlossen oder vom Gerät getrennt werden.
EXPLOSIONSGEFAHR
Der Austausch von Komponenten kann die Eignung für Class I, Division 2 oder Zone 2
beeinträchtigen.
EXPLOSIONSGEFAHR
Öffnen Sie das Gerät nicht bei eingeschalteter Versorgungsspannung.
Allgemeine Hinweise zur Verwendung entsprechend ATEX und IECEx
Treffen Sie Maßnahmen, um transiente Überspannungen von mehr als 40% der
Nennspannung zu verhindern. Das ist gewährleistet, wenn Sie die Geräte ausschließlich
mit SELV (Sicherheitskleinspannung) betreiben.
46
WARNUNG
WARNUNG
WARNUNG
WARNUNG
SCALANCE W786C
Betriebsanleitung, 07/2019, A5E03692138-12