MAINTENANCE
Grease filters
Odour/fine particle filter
EN 8
Saturation of the grease filters
After 30 operating hours, the exhaust setting and 'F' flash alternately on
the display. The grease filters must be cleaned.
Removing the grease filters
Pull the lever down and tilt the grease filter down.
Cleaning the grease filters
• Clean metal grease filters every 2 months or when the display
indicates this.
• Clean either by hand or in the dishwasher, which must be set to a
low temperature and a short cycle.
• The openings must be placed downwards to let the water run out of
the filters.
It is important that the grease filters are properly dried before
replacing them.
Reset the memory after replacing the grease filters. Switch on the
extractor hood and touch and hold the On/Off key for 3 seconds;
'F' will stop blinking.
General:
• More noise is produced when odour filters are used than when the
cooker hood is used with an exhaust vent.
• Odour filters function optimally at a lower motor speed.
Consequently, you should avoid the intensive setting as much as
possible.