Herunterladen Inhalt Inhalt Diese Seite drucken

Power Supply; Charging The Battery Pack; Battery Status - EuroLite AKKU IP UP-4 Entry QCL Spot QuickDMX Montageanleitung

Ip65-akku-uplight mit rgbw-leds, quickdmx und ir-fernbedienung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

POWER SUPPLY

The device can be operated with mains voltage and for mobile use via the internal rechargeable battery.
The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1
Connect the device via the mains cable to a grounded mains socket. Thus the unit is switched on.
2
To switch off the unit, disconnect the power plug.
3
Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains
outlet which is switchable.
4
Please make sure that open contacts are closed with caps in order to avoid humidity and dirt in the
device.

Charging the battery pack

Prior to operating the device off mains for the first time, the rechargeable battery must be fully charged. You
can charge the product using the power cable.
1
Switch on the device with the power button. The operating time of the battery depends on the operating
mode and the ambient temperature (max. 12 hours). After the operation, switch the device off.
2
For charging the battery, connect the device to a power outlet via the power cable provided. Charging
time is 3 hours. The device may be operated during the charging procedure.
3
The device features a protective circuit for charging which prevents overload of the rechargeable battery.
However, disconnect the device from the mains after charging. Otherwise there will be a low current
consumption even if the device is switched off.
4
The device will heat up during charging; this is normal.
5
To prevent damage to the battery by deep discharge, recharge a completely discharged battery as soon
as possible. Do not store the unit with the battery completely discharged and regularly recharge the
battery in case of long storage.
Maximum battery run time
12 hours

Battery status

The battery charge level is shown in the display. The display shows the charge level of the battery in
percent. If the charge level is low, the battery is soon exhausted and must be charged. The device can
continue to be operated in this state for several minutes. Afterwards, a protection circuit against deep
discharge switches the device off automatically.
Recharge time
3 hours
27/36
00133497, Version 1.1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

41700585

Inhaltsverzeichnis