INSTALLATION
Please note: All devices, lighting effects and crossbeams attached on a stand must be secured with a
secondary attachment!
Attach an appropriate adapter or TV-adapter to the top end of the stand and fasten it with the fixation screw.
Attach the mounting bracket of the follow spot onto the TV-adapter and tighten the fixation screw.
The given carrying capacity of the stand must not be exceeded. Please consult the appropriate user manual
for further information.
Caution: The loads have to be installed in a balanced way.
Connection with the mains
Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
OPERATION
After you connected the effect to the mains, the LED SL-150 Search Light starts running.
Via the ON/OFF switch you can turn the device on and off.
Focusing
Step 1: Loosen the focus button on the side of the device.
Step 2: Adjust the focus by sliding the lens housing forward or backward.
Step 3: Tighten the focus button.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tightly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots.
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
International
L
N
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
11/12