Herunterladen Inhalt Inhalt Diese Seite drucken

HYDAC ELECTRONIC EDS 4400 Bedienungsanleitung Seite 20

Druckschalter
Vorschau ausblenden Andere Handbücher für EDS 4400:
Inhaltsverzeichnis

Werbung

EDS 4000 Explosion Proof / Flame Proof
 Stainless steel connection head (model code character Q), manufacturer Pushna,
series 1016 PSEM
- Excerpt CSA certificate:
"Open circuit before removing cover"
- Excerpt ATEX / IECEx certificate:
"No. 8 from Schedule of limitations: Consult the manufacturer if dimensional information on
the flameproof joints is necessary"
Important note for the use in mining applications:
The chemical resistance for transmitters with electrical conduit connection with single leads or
jacketed cable is not tested for the use in mining applications according to ATEX and IECEx
equipment group I.
When used in mining applications a conduit hose or pipe is to be installed at the ½-14 NPT or
M20x1.5 electrical connection and the cable or leads are to run inside the conduit until an area is
reached which is not contaminated with chemicals.
CAUTION !
The programming of the EDS 4000 with the HYDAC Programming Unit HPG 3000 or
ZBE-P1 may only be permitted outside the potentially explosive location !
Edition: 2023-03-16
HYDAC ELECTRONIC GMBH
20
Mat. No.: 669837

Werbung