Problem
No fan blowed out
from air conditioner.
Set temperature can't
be adjusted.
There' s abnormal sound
during operation.
Error Codes
H8
Chassis is full of water.
Malfunction of ambient
F1
temperature sensor.
Malfunction of evaporator
F2
temperature sensor.
Refrigerant is leaking or system is
F0
blocked.
Overload protection for
H3
compressor.
E8
Overload malfunction.
Outdoor tube temperature sensor
F4
is open/short-circuited.
IMPORTANT
If there're following phenomenon, please turn off the air conditioner and disconnect the power immediately,
and then contact dealer immediately:
• Power cord is overheating or damaged.
• Abnormal sound during operation.
• Off-flavor
• Water leakage
Possible Cause
Air outlet or air inlet is blocked.
The unit operates under auto mode.
The required temperature exceeds the
temperature setting range.
The unit is interfered by thunder, radio, etc. Disconnect power, put thro- ugh the
Pour out the water inside chassis. If „H8" still exits, please
contact professional person to maintain the unit.
Please contact professional person to deal with it.
Please contact professional person to deal with it.
Re-energize the unit after turning off and pulling out the plug
for 30 min; If there's still malfunction, please contact after-
sales service.
Check if the unit is under high-temperature and high-
humidity environment; if ambient temperature is too high,
power off the unit and then energize it for operation after the
ambient temperature drops to 35 °C below
Check if the evaporator and condenser are blocked by some
objects; if yes, take away the objects, power off the unit and
then energize it for operation. If the malfunction still occur,
please contact our after-sales service center.
Please contact professional person to deal with it.
Solution
Eliminate the obstacles.
Temperature can't be adjusted under
auto mode.
Temperature setting range: 16°C-30°C .
power again, and then turn on the unit
again.