Herunterladen Inhalt Inhalt Diese Seite drucken

Emergency Off; Heater Coil Error; Power Supply Failure At Last Welding; Technical Specifications - Hürner HCU 300 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HCU 300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
on the load value and is calculated as the current at start
plus 15%.

11.2.8 Emergency Off

The welding process has been interrupted by pressing the
STOP/RESET key.

11.2.9 Heater Coil Error

The dynamic current value during welding differs by more
than 15% from the required value, indicating a short-circuit
in the heater coil.

11.2.10 Power Supply Failure at Last Welding

The last welding is incomplete. The welding unit was dis-
connected from the power supply voltage while it was
in progress. To go on using the unit, this error has to be
acknowledged by pressing the STOP/RESET key (see also
Sect. 9.4).
12
Technical Specifications
Nominal Voltage
Frequency
Output Power
Ingress Protection
Primary Current
Ambient Temperature
+ 140°F)
Output Voltage
Max. Output Current
Memory for Welding Reports 1800 reports
Data Interface Port
(see also the information on the data ports in Sect. 6)
Tolerances:
Temperature
Voltage
Current
Resistance
13

Service and Repair Contact

HÜRNER Schweisstechnik
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Web: www.huerner.de
Version August 2017
230 V
50 Hz / 60 Hz
2800 VA
IP X4
max. 16 A
– 2 0 ° C t o + 6 0 ° C ( – 4 ° F t o
8 V - 48 V
110 A
USB v 2.0 (480 mbit/s)
± 5 %
± 2 %
± 2 %
± 5 %
Tel.: +49 (0)6401 9127 0
Fax: +49 (0)6401 9127 39
E-mail: info@huerner.de
HÜRNER HCU 300 User's Manual
23
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis