Troubleshooting
100M/1G Port Is Not Working
1. Ensure the optical module and cable have no problem.
2. Check if the configuration at both ends of the communication device is auto or forced rate
Connecting the Switch Remotely Unsuccessfully
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check if the corresponding service is enabled.
The Port Is Not Working, the LED Indicator Is Off
1. Ensure the switch ports are in the no shutdown state.
2. Check if the switch can read the DDM information.
3. Check if the port speed setting is correct.
4. Try looping the switch cable.
RJ45 Port Is Not in Connectivity or It Is Erroneous in Receiving/ Transmit-
ting Frames
1. Replace the twisted pair cable.
2. Check if the port configuration has the common working mode with the connected switch.