Herunterladen Inhalt Inhalt Diese Seite drucken

Porthole Kit; Care And Cleaning - Argo Ultra Bedienungsanleitung

Mobiles klimagerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29

PORTHOLE KIT

In the wooden
In the win-
kickboard of a
dow pane
french window

CARE AND CLEANING

WARNING! For safety's sake, be sure to turn the air conditioner OFF and also disconnect it from the power supply before cleaning
it.
1. Cleaning of the Air Filter
The air filter must be checked at least once every two weeks operation. Operation with a dirty filter always causes a lower effi-
ciency of the air conditioner and severe product damage.
The filter can be removed from the upper part of the unit, removing the upper panel and pulling upwards. Use a vacuum cleaner
to remove light dust. If there is sticky dust on the filter, wash it with lukewarm soapy water, then rinse in clean, cold water and dry
it before reinstallation.
FILTER CLEANING
In the wall: you are
recommended
to
insulate the section of
the wall using suita-
ble insulation
If you want to utilise the air conditioner in several rooms, it is
possible to buy varies portholes for air discharge separately.
Filter
ASSEMBLING
Make a hole in the window
pane.
Insert the porthole without the
plug.
Remove the terminal pipe
fitting of the warm air outlet
from the retractile flexible
pipe.
Bring the air conditioner near
the
window
and
insert
the air outlet in the porthole.
EG
9

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis