INSTALLATION MANUAL
This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit.
Special adjustment may be necessary to suit local requirement.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
! WARNING
Installation and maintenance should be performed by qualified persons
who are familiar with local code and regulation, and experienced with
this type of appliance.
All field wiring must be installed in accordance with the national wiring
regulation.
Ensure that the rated voltage of the unit corresponds to that of the
name plate before commencing wiring work according to the wiring
diagram.
The unit must be GROUNDED to prevent possible hazard due to
insulation failure.
All electrical wiring must not touch the refrigerant piping, or any moving
parts of the fan motors.
Confirm that the unit has been switched OFF before installing or servicing
the unit.
Disconnect from the main power supply before servicing the air
conditioner unit.
DO NOT pull out the power cord when the power is ON. This may cause
serious electrical shocks which may result in fire hazards.
Keep the indoor and outdoor units, power cable and transmission wiring,
at least 1m from TVs and radios, to prevent distorted pictures and static.
{Depending on the type and source of the electrical waves, static may
be heard even when more than 1m away}.
Disposal requirements
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household
waste.
Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must
be done by a qualified installer in accordance with relevant local and national legislation.
Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly,
you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for
more information.
Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.

SAFETY PRECAUTIONS

Please take note of the following important points when installing.
Do not install the unit where leakage of flammable gas may occur.
Ensure that drainage piping is connected properly.
Do not overcharge the unit.
Ensure that the unit's panel is closed after service or installation.
Sharp edges and coil surfaces are potential locations which may
cause injury hazards.
Avoid from being in contact with these places.
Before turning off the power supply, set the remote controller's
ON/OFF switch to the "OFF" position to prevent the nuisance tripping
of the unit. If this is not done, the unit's fans will start turning automatically
when power resumes, posing a hazard to service personnel or the user.
Do not operate any heating apparatus too close to the air conditioner
unit. This may cause the plastic panel to melt or deform as a result of
the excessive heat.
Do not install the units at or near doorway.
Do not operate any heating apparatus too close to the air conditioner
unit or use in room where mineral oil, oil vapour or oil steam exist,
this may cause plastic part to melt or deform as a result of excessive
heat or chemical reaction.
When the unit is used in kitchen, keep flour away from going into
suction of the unit.
This unit is not suitable for factory used where cutting oil mist or iron
powder exist or voltage fluctuates greatly.
Do not install the units at area like hot spring or oil refinery plant
where sulphide gas exists.
Ensure the color of wires of the outdoor unit and the terminal
markings are same to the indoors respectively.
IMPORTANT: DO NOT INSTALL OR USE THE AIR
CONDITIONER UNIT IN A LAUNDRY ROOM.
Don't use joined and twisted wires for incoming power supply.
Avoid direct contact of any coil treatment cleaners on plastic part. This
may cause plastic part to deform as a result of chemical reaction.
For any enquiries on spare parts please contact your authorized
dealer.
The equipment is not intended for use in a potentially explosive
atmosphere.
NOTICE
1-2
! CAUTION
If gas leaks and accumulates around the unit, it may cause fire
ignition.
If the drainage piping is not connected properly, it may cause water
leakage which will dampen the furniture.
This unit is factory pre-charged.
Overcharge will cause over-current or damage to the compressor.
Unsecured panels will cause the unit to operate noisily.