Herunterladen Inhalt Inhalt Diese Seite drucken

Placement Of The Submersion Pressure Pump; Commissioning - Renkforce 1519501 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. Placement of the Submersion Pressure Pump

• Attach a sufficiently strong, water-tight rope to the carry handle (1) to lower the submersion pressure pump, e.g.
into a well.
The submersion pressure pump must never be held by the mains cable or attached by the hose! This may
damage the mains cable; there is danger to life from electric shock!
Fasten the rope to a suitable holder.
Never put the submersion pressure pump with the intake opening into dirt, sludge or leaf residue, e.g.
in a rain barrel, because this will clog the submersion pressure pump. We recommend complying with a
minimum distance of 30 cm above ground.
• For connection of the hose, a suitable adapter is required at the outlet opening.
• There is a clamp holder (2) on the side of the carry handle (1). It serves to fasten the cable to the float switch.
The activation/deactivation water level will later result from the position in which the float switch cable is attached.
Fasten the cable to the float switch very carefully and set the correct cable length for your application site.

8. Commissioning

• After lowering the submersion pressure pump into the well, etc. by a rope and fastening the rope accordingly, plug
the mains plug into a properly installed protective ground mains socket. This must be an IP44 mains socket for
operation in the outdoor area.
The mains plug must only be plugged into the mains socket when dry. There is danger to life from electric
shock otherwise!
• When the float switch is placed correctly, the submersion pressure pump will switch on and start taking in water and
transporting it through the exit opening.
If no water is conveyed, there is still air in the submersion pressure pump and the hose. You may be able to ac-
celerate the intake process if you fill water into the submersion pressure pump or the hose, or if you move the
submersion pressure pump slightly back and forth.
• The submersion pressure pump switches off automatically when the float switch drops.
The submersion pressure pump can also be operated manually by fastening the float switch to the submer-
sion pressure pump eyelet accordingly or placing it higher.
The submersion pressure pump must not be operated unsupervised then, because the submersion pres-
sure pump will not switch off if there is no water, which would damage the pump.
20